西门子配电产品(7SJ61/62/63 多功能保护继电器)

西门子配电产品(7SJ61/62/63 多功能保护继电器)

型号︰7SJ61/62/63/6

品牌︰西门子

原产地︰德国

单价︰-

最少订量︰1 件

现在查询

产品描述


 Protection Devices        
 > 6MD61x I / O Box
  > 6MD63x Medium Voltage Bay Unit
  > 6MD662-664 Bay Control Unit
  > 6MD665 Bay Processing Unit
  > 7PA2 / 3 Relays for high responsibility applications
  > 7RE28x Voltage Balance Relay
  > 7RW600 Voltage- / Frequency Protection
  > 7SA522 Distance Protection
  > 7SA6xx Distance Protection and Control
  > 7SD52x / 53x Differential Protection for 2 - 6 Line-Terminals with Distance Protection
  > 7SD600 Line Differential Protection for one pilot wire pair
  > 7SD610 Universal Two-Terminal Differential Protection
  > 7SJ45 easy Numerical overcurrent protection
  > 7SJ46 easy Numerical overcurrent protection
  > 7SJ600 Overcurrent, Motor and Overload Relay
  > 7SJ601 Overcurrent, Motor and Overload Relay
  > 7SJ602 Overcurrent and Overload Relay
  > 7SJ61x Multifunction Protection
  > 7SJ62x Multifunction Protection
  > 7SJ63x Multifunction Protection
  > 7SJ64x Multifunction Protection with Synchro Function
  > 7SJ80x Multifunction Protection Relay
  > 7SK80x Motor Protection Relay
  > 7SN600 Transient Earth-Fault Relay
  > 7SS52x Distributed Busbar and Circuit-Breaker Failure Protection Relay
  > 7SS60x Centralized Numerical Busbar Protection
  > 7ST61x / 63x Overhead Contact-Line Protection for AC Traction Power Supply
  > 7SV600 Numerical Circuit–Breaker Failure Protection Relay
  > 7TS15 / 16 Annunciation Relay
  > 7UM61x Multifunction Generator Protection Relay
  > 7UM62x Multifunction Generator Protection Relay
  > 7UT612 Multiple function protection for two winding transformers
  > 7UT613 / 63x Differential protection for transformers (2 - 5 windings / ends)
  > 7UW50x Tripping Matrix
  > 7VE6xx Multifunction Paralleling Device
  > 7VH60x High Impedance Differential Relay 
  > 7VK61x Breaker Management Relay
  > 7VP15x Portable Test System
  > 7XV75x Test Switch
     

  > 7SA510 Distance Protection
  > 7SA511 Distance Protection
  > 7SA513 Line Protection Relay
  > 7SA518 Overhead Contact-Line Protection Relay
  > 7SA519 Overhead Contact-Line Protection Relay
  > 7SD502 Line Differential Protection with two Pilot-Wires
  > 7SD503 Line Differential Protection with three Pilot-Wires
  > 7SD511 Current Comparison Protection Relay
  > 7SD512 Current Comparison Protection Relay with AR
  > 7SJ50x Overcurrent-Time Protection Relay
  > 7SJ511 Overcurrent-Time Protection Relay
  > 7SJ512 Overcurrent-Time Protection Relay
  > 7SJ531 Line and Motor Protection
  > 7SJ551 Multi-Function Protection Relay
  > 7SS50x Busbar / Circuit-Breaker Failure Protection Relay
  > 7UT51x Differential Protection Relay
  > 7SV512 Numerical Circuit–Breaker Failure Protection Relay
  > 7SV73x Power Supply Unit
  > 7UM511 Generator Protection
  > 7UM512 Generator Protection Relay
  > 7UM515 Generator Protection Relay
  > 7UM516 Generator Protection Relay
  > 7VE51x Synchronizing Unit
  > 7VH80x High Impedance Differential Relay (1 Pole) 
  > 7VH83x High Impedance Differential Relay (3 Pole) 
  > 7VK512 Auto–Reclose Relay

产品规格︰ 用 途:

▲ 可用在配电线、输电线作保护和监控。

▲ 可用于不同电压等级的中性点直接接地、小阻抗接地、不接地或补偿接地的网络。

▲ 适用于辐射式、环状网或单端和多端供电的线路。

▲ 可实现对不同电压等级的线路、变压器、发电机、电动机、电容器和母线的保护

性能特点:

▲ 功能强劲的32位微处理器。

▲ 对测量值进行持续监视,装置的软、硬件都有连续的自检功能。

▲ 友好的操作界面。

▲ 完全数字化的处理过程及测量值的控制,`完成由模拟量输入到开出量的输出。

▲ 励磁涌流的二次谐波制动。

▲ 动态冷负载启动功能。

▲ 记录事件信息、故障数据及故障录波用于分析和寻找故障。

▲ 通过串口可用数据电缆、Modem或光缆与SCADA或变电站装置通讯。

▲ 可选用一些附加的保护和控制功能。

▲ 可编组的二进制输入和继电器输出。

主要功能:

保护功能------ 相间和接地时限过流保护,各两段,均可选择定时限或反时限;

方向时限过流保护,两段,均可选择定时限或反时限;

灵敏接地故障检测;

负序电流保护;

电压(低电压和过电压)保护;

频率(低频和高频)保护;

热过负荷保护;

断路器失灵保护;

自动重合闸(1次到9次);

电动机启动保护;

测量功能-------- 可测相电流、相电压、线电压、正序电流、正序电压、负序电流、负序电压、零序电流、零序电压、有功功率、无功功率、视在功率以及功率因素和频率(7SJ61只能测电流)。

通信功能------- 同步时钟接口A:对时。

系统接口B:RS232、RS485或光纤口,采用IEC870-103或Profibus或Modbus规约.

DIGSI4/调制解调器接口C:RS232、RS485或光纤口。

操作员接口:装于前面板,RS232口,用于连接AT或PC机,用于调试。

其它功能-------- 可以利用装置配置软件DIGSI4中的可编程逻辑编辑新的逻辑功能,以满足一些特殊要求。

内部时钟可通过IRIG-B(或DCF77)信号、二进制输入信号或系统接口命令实现同步。

以时间次序记录和保存 8次故障,事件信号及80条与故障不直接相关的状态动作信号。

记录、保存、传送故障波形。

断路器统计,包括跳闸次数及断路器切断时的每相电流。

记录被保护装置的运行时间。

结构安装:

采用7XP20箱体,7SJ61/62为